A series of experiments were conducted to determine airborne particulate emissions during a variety of normal activities on hard and carpeted floors. Surfaces were uniformly seeded with test dust. Activities tested included: dust mopping a hard surface; vacuuming a carpet with a Carpet and Rug Institute (CRI) Green Label-approved vacuum; vacuuming a carpet with a non-CRI-approved vacuum; walking on a hard surface; and walking on a carpet.
We do not strictly control Google ad content. If you believe any Google ad is inappropriate, please email us directly here.
For the dust mopping experiment, dust was first permitted to settle for fourteen minutes, at which time no airborne particles (0.0 micrograms/meter3) were detected. Dust mopping was begun at a walk rate average of 3.8 feet/second. At 30 seconds of dust mopping, the airborne particulate count rose to 46.2 micrograms. At 1 minute the airborne particulate counts increased to 353.9 micrograms/meter3. The airborne particle counts rose steadily until at 11 minutes of mopping a peak concentration of 2032.9 micrograms/meter3 was detected.
For the non-CRI-approved vacuum experiments, dust was allowed to settle for 4 minutes at which time the airborne particle levels ranged between 0.4 and 0.8 micrograms/meter3. The vacuum was turned on but kept stationary over a dust-seeded test carpet for 10 minutes. Airborne particle levels increased slowly from 1.0 to 6.3 micrograms/meter3 over the 10 minute period. At this point, the vacuum was mobilized at a rate of 1.8 feet per second. Within ninety seconds, the airborne particle level rose to 463.3 micrograms/meter3. The peak airborne level was reached 30 seconds later at 553.7 micrograms/meter3. (Note: This is 15.6 times the peak level detected with the CRI approved Green Label vacuum tested. See below.) Over the remaining 8 minutes of the experiment, the airborne particle levels declined to a final level of 156.1 micrograms/meter3. The vacuum was turned off and the particle level was tracked for 4 minutes. At the end of this period, the airborne particle level had fallen to a level of 136.0 micrograms/meter3.
For the CRI Green label-approved vacuum experiments, dust was again allowed to settle for 4 minutes, at which time airborne particle levels ranged between 0.6 and 1.1 micrograms/meter3. The vacuum was turned on and kept in a stationary position over a dust-seeded test carpet for 10 minutes. Airborne particle levels increased slowly from 0.9 to 8.7 micrograms/meter3. At this point the vacuum was mobilized at a rate of 1.8 feet per second. At 1 minute of operation a peak particle level of 35.4 micrograms/meter3 was reached. Over the next 90 seconds, this level declined to 26.2 micrograms/meter3. Over the rest of the 10 minute experiment, the airborne particle levels ranged between 25.9 and 21.9 micrograms/meter3. The vacuum was turned off and the particle level was tracked for 4 minutes. At the end of this period, the airborne particle level had fallen to a level of 18.9 micrograms/meter3.
For the walking experiments, a similar protocol was followed. A hard surface and carpet were seeded with test dust. The test walker stood quietly for 4 minutes, at which time in both hard surface and carpet area cases, the airborne particle levels were steady for the entire period at 0.0 micrograms/meter3.
On the hard surface floor, the test walker then began walking at a rate of 3.8 feet per second for 18 minutes. At 1 minute, the airborne level had risen to 15.1 micrograms/meter3. At 2 minutes, the level was 91.3 micrograms/meter3. The airborne particle levels rose steadily over course of the entire 18 minute walk. The peak concentration was 943.4 micrograms/meter3 reached at 17 minutes. This level is 8.9 times the peak level seen on a carpeted surface.
For the carpet walking experiment, the airborne particle levels were steady for the entire 4 minute settling period at 0.0 micrograms/meter3. When walking began, the particle levels increased to 7.8 micrograms/meter3 at 30 seconds and 14.4 micrograms/meter3 at 1 minute. The rise in particle levels was much more gradual. The peak level of 105.6 micrograms/meter3 was reached at 10 minutes of walking. (Note: this peak level was not exceeded in three replicates of this experiment). The levels then began to decline, so that at the end of the 13 minute walk the airborne particle level was 81 micrograms/meter3.
Source: "Cleaning and Foot Traffic Emissions Analysis"
Asbury, G - Test Number 0072198. Professional Testing Laboratory, Inc., Dalton, GA. Unpublished data. 16 pages. May, 2002.
The Carpet & Rug Institute (CRI)
P.O. Box 2048
Dalton Georgia 30722
carpet-rug.org
(Note: The views expressed in this article are those of the authors, and do not necessarily represent those of The Healthy House Institute, LLC.)
HHI Error Correction Policy
HHI is committed to accuracy of content and correcting information that is incomplete or inaccurate. With our broad scope of coverage of healthful indoor environments, and desire to rapidly publish info to benefit the community, mistakes are inevitable. HHI has established an error correction policy to welcome corrections or enhancements to our information. Please help us improve the quality of our content by contacting allen@healthyhouseinstitute.com with corrections or suggestions for improvement. Each contact will receive a respectful reply.
The Healthy House Institute (HHI), a for-profit educational LLC, provides the information on HealthyHouseInstitute.com as a free service to the public. The intent is to disseminate accurate, verified and science-based information on creating healthy home environments.
While an effort is made to ensure the quality of the content and credibility of sources listed on this site, HHI provides no warranty - expressed or implied - and assumes no legal liability for the accuracy, completeness, or usefulness of any information, product or process disclosed on or in conjunction with the site. The views and opinions of the authors or originators expressed herein do not necessarily state or reflect those of HHI: its principals, executives, Board members, advisors or affiliates.